S4K 4U-C 6kVA 6U-C 10kVA
SolaHD™ S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS
S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPSs are the first true online industrial uninterruptible power systems that provide flexible output voltage, an integrated maintenance bypass switch, and internal batteries all in a slim 4U (7.0") or 6U (10.5") enclosure. They feature a double-conversion topology to provide the ultimate protection against a wide range of potential power problems.
Features
- cULus, Federal Communications Commission
- True double-conversion topology. User-replaceable, the hot-swappable internal battery module
- Higher power factor of 0.80 (6kVA) and 0.90 (10kVA). Automatic frequency detection (60 or 50 Hz)
- Both models offer 208/120V or 240/120V
- Configurable as a tower or rack mounting. Easily installed in 18” to 32” deep rack using rack mount kit # SRS1832
- Highest density, 6 kVA in only 4U and 10 kVA in only 6U of rack space
- Includes both automatic and manual maintenance bypass switch
- Self-diagnostics simplify maintenance and troubleshooting
- Remote Emergency Power Off (REPO)
Specifications
| Capacity | (VA/W)6000/4800, 10000/9000 |
|---|---|
| Typical Back-up Time (minutes, full/half load) | Internal Battery 6000/4800: 4/13; 10000/9000: 5/14 |
| Audible Noise | Less then 55 dBA @ 3.2FT rear, Less then 50 dBA @ 3.2FT front/sides |
| Hertz | 50 or 60 Hz |
| Input Voltage Range | 120/208 Vac at 120 °C |
| Nominal Voltage Range | 120/208 Vac |
| Number of Phases | Single Phase |
| Operating Temperature | 0°C to +40°C |
Important Safety PRECAUTIONS
SAVE THESE INSTRUCTIONS
This manual contains important safety instructions. Read all safety and operating instructions before operating the Uninterruptible Power System (UPS). Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. This equipment can be operated by individuals without previous training.
This product is designed for commercial/industrial use only. It is not intended for use with life support or other designated “critical” devices. Maximum load must not exceed that shown on the UPS rating label. The UPS is designed for data processing equipment. If uncertain, consult your dealer or local SolaHD representative.
This up is designed for use on a properly grounded (earthed) 50 or 60 Hz supply. The factory default setting is 120/208 Vac, 60 Hz. Installation instructions and warning notices are in this manual.
The S4KC is designed for use with a four-wire input (L1, L2, N, G).