Posts

Eaton 9390 - 80kVA

Image
The energy-efficient Eaton 9390-80 Model – 80kVA 208V UPS provides backup power and scalable battery runtimes in a small footprint for mid-size data centers, medical equipment, and other critical systems. With the groundbreaking Energy Saver System, the 9390 operates at 99% UPS efficiency and can pay for itself in three to five years—without sacrificing reliability. General • Efficiency- 99% with Energy Saver Mode • Parallel Capability- Four modules with tie cabinet • Audible Noise- <65 dBA @ 1 meter • Altitude (max)- 2000m at 104°F (40°C) Input • Voltage- 208,380,400,415,480,600 • Voltage Range- +10% / -15%2 • Frequency range- 55-65 Hz • Power Factor- 0.99 (min) • Input Current Distortion- • Soft Start Capability- Yes • Internal Backfeed Protection- Yes • Broadcast global support- Yes Output • Voltage- 208,380,400,415,480,600 • Regulation- ±1% • Inverter- PWM with IGBT Switching • Voltage THD- < 2% (100% linear load);< 5% (non-linear load) • Load Power Factor Range- Down to 0...

S4K 4U-C 6kVA 6U-C 10kVA

Image
SolaHD™ S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPSs are the first true online industrial uninterruptible power systems that provide flexible output voltage, an integrated maintenance bypass switch, and internal batteries all in a slim 4U (7.0") or 6U (10.5") enclosure. They feature a double-conversion topology to provide the ultimate protection against a wide range of potential power problems. Features cULus, Federal Communications Commission True double-conversion topology. User-replaceable, the hot-swappable internal battery module Higher power factor of 0.80 (6kVA) and 0.90 (10kVA). Automatic frequency detection (60 or 50 Hz) Both models offer 208/120V or 240/120V Configurable as a tower or rack mounting. Easily installed in 18” to 32” deep rack using rack mount kit # SRS1832 Highest density, 6 kVA in only 4U and 10 kVA in only 6U of rack space Includes both automatic and manual maintenance ...

12V LFeLi Battery

Image
Specification Model voltage Rated Capacity Length Width Height TH Weight V Ah mm in. mm in. mm in. mm in. kg lbs LFeLi-1207M 12.8 7 151 5.94 65 2.56 93.5 3.68 99 3.9 0.9 2.1 LFeLi-1209M 12.8 9 151 5.94 65 2.56 93.5 3.68 99 3.9 1.0 2.2 LFeLi-1212M 12.8 12 151 5.94 98 3.86 95 3.74 101 3.98 1.9 4.2 LFeLi-1220M 12.8 20 181.5 7.15 77 3.03 167.5 6.59 167.5 6.59 2.6 5.7 LFeLi-1233M 12.8 33 166 6.54 175 6.89 125 4.92 125 4.92 4.2 9.3 LFeLi-1240M 12.8 40 197 7.76 165 6.5 170 6.69 170 6.69 5.4 11.9 LFeLi-1250M 12.8 50 257 10.12 132 5.2 200 7.87 200 7.87 7.0 15.4 LFeLi-1255M 12.8 55 257 10.12 132 5.2 200 8.07 211 8.31 7.4 16.3 LFeLi-1260M 12.8 60 260 10.24 168 6.61 208 8.07 211 8.31 8.4 18.5 LFeLi-1275M 12.8 75 260 10.24 168 6.61 208 8.19 214 8.43 9.3 20.5 LFeLi-12...

715KVA CAT C18

Image
The C18 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 550 to 850 kVA at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. Our C18 generator sets range from low fuel consumption systems to EPA Stationary Emergency (Tier 2) certified. Seismic certification is also available for select models, so you can deliver power despite disturbances. The EMCP 4.2 and optional 4.2B control panels offers fully featured power metering with communications via Modbus RS-485, SCADA, or CAN data links. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. All C18 generator sets are supplied with 4 years Extended Service Coverage when used in a standby application (ESC - for industry leading warranty cover...

APC 3 KVA Smart Sine Wave

Image
price/PKR 358,400.00   size/2 KVA/3 KVA Product Description does not contain textiles/fur Made in USA 3000VA / 2700W Pure Sine Wave UPS battery backup Smart-UPS Extended Run Option: Extended-run models accept external battery packs (model SMX120BP, sold separately) for a longer runtime during prolonged outages, to power critical servers, security and communications systems Input: NEMA 5-30P. Output: NEMA 5-15R (6), 5-20R (3) and L5-20R (1) Pre-Installed Network Management Card with environmental Monitoring (APC model AP9631) Output: 120V (User-selectable 100V-127V). Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz Sync to mains Tower. 4U Rackmount convertible (rail kits sold separately, part # AP9625) Product information APC Network UPS, 3000VA Smart-UPS Sine Wave, Short Depth UPS with Extended Run Option, SMX3000LVNC, Network Management Card, Tower/4U Rack Convertible, Line-Interactive, 120V black Size:3000VA | Style:+ NMC | Pattern Name:Battery backup T...

Eaton 5P Tower UPS

Image
Eaton 5P Tower UPS 5P1500 1500VA TOWER LCD 120V 1.44 kVA/1.10 kW Tower 0.07 Hour Full Load - 8 x NEMA 5-15R Brand Eaton Battery Cell Composition Sealed Lead Acid Item Dimensions LxWxH 5.91 x 17.52 x 9.06 inches Item Weight 16 Pounds Wattage 1100 watts About this item Product Name: 5P Tower UPS Product Type: Line-interactive UPS Plug/Connector Type: NEMA 5-15P Receptacles: 8 x NEMA 5-15R Interfaces/Ports: RJ-45 RS-232 USB Network Management: Optional Batteries: Maintenance-free, Sealed Lead Acid Hot-swappable Backup/Run Time:  0.07 Hour 1.10 kW Full Load, 0.22 Hour 550 W Half Load Capacity: 1.44 kVA/1.10 kW Input Voltage: 110 V...

Eaton 9E in 1 kVA UPS

Image
Eaton 9E in 1 kVA UPS Online Double Conversion with Internal Batteries Technical Details Brand Eaton Manufacturer Eaton Model 9103-53862XT1 Product Dimensions 35.6 x 14.4 x 22.8 cm; 9.2 Kilograms Batteries 2 12V batteries are required. (included) Item model number 9103-53862XT1 Special Features Active Input Power Factor Correction 0.99., Double Conversion Efficiency >91% & ECO mode efficiency up to 98%, Inbuilt OVCD (Over Voltage Cut-off device), 100% load @ 0~40C operating temp., IGBT based Rectifier True Online, Double Conversion Robust design, O/P power factor 0.9 (O/P power factor 0.8 for long backup model), Digital Charger Technology provides 02-10A charging current, Generator Compatible with Wide Input voltage window Mounting Hardware 1kVA UPS with Inbuilt batteries 9AH x 2 ...